MIL-F-24702/1A(SH)
REQUIREMENTS:
Elements:
The filter element shall be in accordance with figure 1.
1.
Rated flow in accordance with MIL-H-17672, 2135 T-H fluid at 40° C
2.
temperature - see table I.
3.
Minimum beta ratio - see table I.
4.
Air clean fine test dust (A.C.F.T.D) capacity - 35 grams.
Terminal pressure drop - 40 psi at rated flow.
5.
Clean element pressure drop at rated flow and 68 centistoke (minimum)
6.
viscosity - 10 psi maximum.
Collapse burst pressure - 150 psi minimum.
7.
8.
Reverse flow pressure - 15 psi minimum.
Bubble point - 6 inches of water minimum.
9.
Flow fatigue cycles - 50,000 cycles.
10.
TABLE I.
Minimum beta ratio.
Elements Connetor:
Element connector shall be in accordance with figure 2.
1.
Material shall be nylon or equivalent.
2.
2of3