MIL-DTL-24402/1A
PART NUMBER CROSS REFERENCE. Table I provides a cross reference between old (MIL-F-24402D and
earlier) and new part numbers.
TABLE I. Cross reference of part numbers.
New part numbers
Old part numbers
(Fatigue rated) 1/
(Non-fatigue rated) 1/
(Fatigue rated) 2/
(Non-fatigue rated) 2/
M24402/1NB
-
M24402-1N-BP-3
M24402-1N-BP-0
-
M24402/1NC
M24402-1N-CP-3
M24402-1N-CP-0
M24402/1RB
-
M24402-1R-BP-3
M24402-1R-BP-0
-
M24402/1RC
M24402-1R-CP-3
M24402-1R-CP-0
NOTES:
1/
If a differential pressure indicator is to be acquired with the filter assembly, add the
appropriate indicator dash number suffix from MIL-DTL-24402/5.
2/
Add E, G, or M depending on the form of differential pressure indicator acquired with the
filter assembly, as follows:
E
-
Electrical with mechanical pop-up indicator.
G
-
Gauge type indicator.
M
-
Mechanical pop-up indicator.
SUBSTITUTION OF ASSEMBLIES. Assemblies with new fatigue rated part numbers may be substituted for all
assemblies with old part numbers as shown in table I. Assemblies with new non-fatigue rated part numbers may
only be substituted for assemblies with non-fatigue rated part numbers as shown in table I. Only assemblies with
old fatigue rated parts numbers may be substituted for assemblies with new fatigue rated part numbers. Assemblies
with old fatigue rated and non-fatigue rated part numbers may be substituted for assemblies with new non-fatigue
rated part numbers as shown in table I.
REQUIREMENTS.
a.
Configuration. The filter assemblies shall meet the dimensional requirements shown on figure 1 for filter
housings with Size B elements installed and figure 2 for filter housings with Size C elements installed.
b.
Maximum rated operating pressure. The filter assemblies shall have a maximum rated operating pressure
of 3,000 lb/inē.
c.
Rated flow capacity. The filter assemblies with Size B elements installed shall have a rated flow capacity
of 50 gallons per minute. The filter assemblies with Size C elements installed shall have a rated flow
capacity of 25 gallons per minute.
d.
Performance.
(1) Bypass relief requirements. Type R assemblies shall have bypass relief valve settings as specified in
table II.